24/7 Phone Services 0086(371)86151827
Send to E-mail [email protected]
[email protected] Xincheng Science & Technology Building High-Tech Development Zone, Zhengzhou, China

30 ft in diameter API 650 tank foundations for leak detection

30 ft in diameter API 650 tank foundations for leak detection

30 ft in diameter API 650 tank foundations for leak detection

Some defects may be found after the regular safety inspection for the 30 ft in diameter API 650 tank. The common 30 ft in diameter API 650 tank defects are: Tank cracks, tank welding defects. The cracks on the base metal, surface and near surface of the tank wall shall be eliminated by grinding with circular arc, and then magnetic particle inspection or re inspection shall be carried out. Cracks in heat affected zone: generally, grinding method is used to eliminate cracks, and magnetic particle or dye flaw detection is used to confirm that there is no crack, and then repair welding or grinding smooth transition.

Shell Stiffening Rings for Tanks That Contain Liquid
Internal or external shell stiffening rings may be required to maintain roundness when the tank is subjected to wind, vacuum, or other specified loads. When 30 ft in diameter API 650 tank stiffening rings are required, the stiffener-to-shell weld details shall be in accordance with Figure Q-1 and Q.3.5.2 through Q.3.5.5.
Three-plate laps or butt-weld junctions in tank bottoms shall be not closer than 12 in. from each other or from the butt-welds of the annular plates.
Bottom plates, other than annular bottom plates for a 9% or 5% nickel steel or stainless steel tank that contains liquid, may have a minimum thickness of 3/16 in. exclusive of any specified corrosion allowance.

Large net shell API 650 tanks or net shell of tank 30 ft in diameter API 650 tank is a tank top for the surface grid structure and the physical structure form of truss structures, thin shell structure is reasonable, mainly for the top using triangle net shell, socket type net shell or meridian reticulated shell technology for the design of 30 ft in diameter API 650 tank large-scale tank top, its great spanning capacity and uniform stress, good rigidity, less material, convenient assembly, safe and reliable.

When providing technical services on site, the after-sales personnel shall strictly abide by the safety rules and regulations of the construction site, consciously take safety protection measures (such as wearing safety helmet when entering the construction site), accept the supervision and management of the site; without permission on the construction site, they shall not dismantle, smear or damage any goods; the commissioning of contract goods shall be carried out under the supervision of the site supervisor If necessary, it shall be approved by the site supervisor or the person in charge of the project department.

Previous : 75 ft in diameter API620 oil tank depth of fusion

Next : The lowest design temperature of api 650 crude oil storage tank standard pdf

Leave a message