API 620 welded steel flat-bottom tanks with a ringwall foundation

API 620 welded steel flat-bottom tanks with a ringwall foundation

API 620 welded steel flat-bottom tanks with a ringwall foundation

The increased uplift described in API Standard 620 tank Appendix Q is intended to apply to the size of the ringwall and foundation but not the anchorage. For tanks with an internal design pressure of 1 lbf/in.2 gauge and over, the uplift, if any, shall be calculated under the combined conditions of 1.25 times the internal design condition plus the design wind load on the API 620 welded steel flat-bottom tanks shell and roof.

The main content of the inspection of the safety management of metal atmospheric API 620 welded steel flat-bottom tanks is whether the filed data of the storage tanks are complete; whether the operators have received safety management training; whether the problems detected in the past have been resolved. The main inspection content of the tank body of the metal atmospheric pressure storage tank is whether the tank top, tank wall, and bottom plate of the storage tank are deformed, dented, seepage and perforation, etc.; whether the API 620 welded steel flat-bottom tanks accessories are complete and whether there are any abnormalities; No sinking, tilting, etc.

Every after-sales service shall have a detailed record of the customer's product problems and handling methods. The records shall be sorted into volumes and filed on a monthly basis, and submitted to the technical department for filing. The problems found in the after-sales service shall be summarized in a timely manner, discussed with the technical department, the quality inspection department and the production department, and a proper solution shall be proposed for the technical department to improve in a timely manner;

The thickness of the overburden on the top of the API 650 oil tank should not be less than 0.5m. The surrounding backfill with clean sand or fine soil should be no less than 0.3m thick; the API 650 oil tank API 620 welded steel flat-bottom tanks operation platform ladder selection unit is considered in a unified manner. The buried operation well is designed for buried horizontal oil tanks, and the two are compatible.

Previous : API oil storage tank standard 620 anchorage forces

Next : API620 large vertical storage tanks foundations roof legs