Fabrication of API650 spherical tank sidewall plate material

Fabrication of API650 spherical tank sidewall plate material

Fabrication of API650 spherical tank sidewall plate material

The refrigerated tank primary components shall include, but will not be limited to, the following parts of a single-wall tank or of the inner tank API650 spherical tank sidewall plate material in a double-wall tank: shell plates; bottom plates; knuckle plates; compression rings; and shell manways and nozzles including reinforcement, shell anchors, piping, tubing, forgings, and bolting. Roof nozzles in contact with the refrigerated liquid shall be considered primary components.

Our after sales department is an very important part of our department structures. After the customer receive steel materials, our after sales department will follow up regularly and solve problems for them in time if they have the needs. We romise to return the goods for free for its lifetime if it is quality of the steel material itself. Meanwhile, if you have any advice or complaints, also welcome to feed back to our after sales department, and we are trying to give better service to you.

The company's business philosophy: customer satisfaction is the most important measure of our work performance; employees are the company's most important wealth; the improvement of employees' quality and professional knowledge is the growth of the company's wealth; employees' welfare and living standards are the concrete embodiment of the company's business performance; product and service quality are the lifeblood of the company's development; brand is the company's products and A mirror of service; recognition of the market is the foundation of the company's survival.

For API 650 tanks Projection from outside of tank shell to extreme face of flange - plus or minus 5 mm. API650 spherical tank sidewall plate material Elevation or radial location - plus or minus 6 mm. API 650 tanks Flange tilt in any plane, measured on the diameter across the gasket surface - plus or minus degree but not exceeding 5 mm. Flange bolt hole orientation - plus or minus 2 mm.

Previous : Design and construction requirements for API620 conical-roof tank

Next : API 620 oil storage tank material seismic use group iii