Atmospheric fixing roof oil storage tank inspection includes annual inspection and comprehensive inspection. Annual inspection is an inspection during operation to ensure the safety of atmospheric storage tanks during the overhaul period, at least once a year. Comprehensive inspection is a more comprehensive inspection of atmospheric storage tanks according to a certain inspection cycle. The inspection content of metal atmospheric fixing roof oil storage tank includes the safety management of the storage tank, the inspection of the tank body and its operating conditions, etc.

The company has a mature technical team whose reponsibility is to design the drawing, choose suitable material and evaluate the whole production processaccording to customers’ requirement. The company is led by talents and technology, and comprehensively promotes its six business segments like steel material supply, precision steel casting, environmental protection equipment, household appliance, fixing roof oil storage tank steel structures and oil tank projects. Seeking new developments in new technology and business areas, and fostering a large number of industry-leading, international-level projects.

The company has our own truck fleet, and can transfer products flexibly and quickly. At the same time, we have large warehouses near the ports of Tianjin and Shanghai, so as to ensure that we can deliver high-quality products to customers in the first time. At the same time, it also greatly reduces the transportation cost, and realizes the double harvest of time benefit and economic benefit. Time guarantee is one of the important strengths of our service.

Shell Stiffening Rings for Tanks That Contain Liquid
Internal or external shell stiffening rings may be required to maintain roundness when the tank is subjected to wind, vacuum, or other specified loads. When fixing roof oil storage tank stiffening rings are required, the stiffener-to-shell weld details shall be in accordance with Figure Q-1 and Q.3.5.2 through Q.3.5.5.
Three-plate laps or butt-weld junctions in tank bottoms shall be not closer than 12 in. from each other or from the butt-welds of the annular plates.
Bottom plates, other than annular bottom plates for a 9% or 5% nickel steel or stainless steel tank that contains liquid, may have a minimum thickness of 3/16 in. exclusive of any specified corrosion allowance.

Previous : API 620 low-pressure oil storage tanks snow load

Next : API oil storage tank standard 620 anchorage forces

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12