horizontal oil transportation vessel and tank butt-welded spherical dome

horizontal oil transportation vessel and tank butt-welded spherical dome

horizontal oil transportation vessel and tank butt-welded spherical dome

The main content of the inspection of the safety management of metal atmospheric horizontal oil transportation vessel and tank is whether the filed data of the storage tanks are complete; whether the operators have received safety management training; whether the problems detected in the past have been resolved. The main inspection content of the tank body of the metal atmospheric pressure storage tank is whether the tank top, tank wall, and bottom plate of the storage tank are deformed, dented, seepage and perforation, etc.; whether the horizontal oil transportation vessel and tank accessories are complete and whether there are any abnormalities; No sinking, tilting, etc.

Since its inception, the company has always adhered to the development policy of "survival with quality, development with products, cooperation with credibility, and service with customers". I would like to express my heartfelt thanks to the old and new friends and customers who have always given care, support and help to the company! And sincerely hope to establish a long-term cooperative relationship with them, mutual benefit and common development.

Impact Test Requirements for Oil Storage Tanks Primary Components
All horizontal oil transportation vessel and tank primary components of 9% or 5% nickel steel shall be impact tested in accordance with Q.2.2.2 through Q.2.2.4. Impact testing is not required for primary components of austenitic stainless steel, nickel alloy, and aluminum materials. Welds in high-alloy (austenitic) stainless steel shall be impact tested if required by Q.6.3.
Impact testing of plates, including structural members made of plate, shall comply with the following:a)Impact test specimens shall be taken transverse to the direction of final plate rolling. b)Charpy V-notch specimens shall be cooled to a temperature of –320°F for A353, A553, and A645 steels for impact testing.

Previous : API620 external floating roof tanks bottom plates welded to the shell

Next : 60ft diameter field assembled large storage tanks