LNG containment and insulation systems vacuum testing

LNG containment and insulation systems vacuum testing

LNG containment and insulation systems vacuum testing

Density of LNG containment and insulation systems Liquid Stored
The density of the liquid stored shall be its maximum density within the range of design temperatures, but no less than 29.3 lbf/ft3 for methane, 34.21 lbf/ft3 for ethane, and 35.5 lbf/ft3 for ethylene.
Design Metal Temperature
The design metal temperature of each component exposed to the liquid or vapor being stored shall be the lower of the temperatures specified as follows: The design metal temperature of the components of the API 620 single-wall tank or the inner tank of a double-wall tank shall be the minimum temperature to which the tank contents shall be refrigerated, including the effect of subcolony at reduced pressure.

Using advanced logistics management, advanced models and management experience to increase the reliability of logistics operations and provide customers with 24/7 cargo management. On the premise of reducing transportation and management costs as much as possible, we provide customers with high-quality and efficient services; good business reputation has been recognized and supported by our customers.

Our company will set up a full-time service engineer for the project, who is responsible for the interface and coordination of technical support and after-sales service of the LNG containment and insulation systems project. In response process of customer service center, in case of technical support and after-sales service demand, the user shall contact the full-time engineer of LNG containment and insulation systems customer service center, and the technical personnel will give corresponding answers and on-site treatment according to the needs of users.

The tank wall design of API 650 oil storage tank. Since there is no ventilation pipe directly connected with the outside on the top of the LNG containment and insulation systems tank, the ventilation between the inside and outside of API 650 oil storage tank is realized by the respiration valve. The constant pressure of the respiration valve is 0.3kPa, so the pressure on the top of the tank is 0.3kPa.

Previous : LNG storage yanks tests of new design

Next : LNG tank for oil and gas industry internal components