24/7 Phone Services 0086(371)86151827
Send to E-mail [email protected]
[email protected] Xincheng Science & Technology Building High-Tech Development Zone, Zhengzhou, China

offer API620 steel storage tank ASTM A216 external floating roofs

offer API620 steel storage tank ASTM A216 external floating roofs

offer API620 steel storage tank ASTM A216 external floating roofs

The horizontal projection of the roof plate within the compression-ring region is 4.9 x 0.866 = 4.25 in., which fulfills the requirement of API 620 tank standard 5.12.5.1. The required area and horizontal projection can be provided by any of the standard angles listed in Table F-3.
Any of these angles may be used in accordance with the details of Figure 5-6, detail a or b, but if details c, h, or i in Figure 5-6 were intended, the net area of the angle must be calculated by deducting the area expected to be lost by corrosion from that part of the angle surface that is exposed to the interior of the tank.

In the process of offer API620 steel storage tank steel transportation, enterprises often use railway transportation, highway transportation, water transportation and other ways to transport. According to the cargo owner's requirements on the timeliness of the goods and the different transportation routes, our company will choose offer API620 steel storage tank different modes of transportation. According to the specific needs of customers, or specify the mode of transportation.

Every after-sales service shall have a detailed record of the customer's product problems and handling methods. The records shall be sorted into volumes and filed on a monthly basis, and submitted to the technical department for filing. The problems found in the after-sales service shall be summarized in a timely manner, discussed with the technical department, the quality inspection department and the production department, and a proper solution shall be proposed for the technical department to improve in a timely manner;

While GB50341 generally takes the weld coefficient as 0.9;When the minimum yield strength of offer API620 steel storage tank steel plate is greater than 390 MPa, take 0.85. The thickness of API 650 tanks is generally smaller than that of GB50341, and this difference is particularly evident in the design of large tanks, where the overall weight of the tanks varies greatly.

Previous : api 650 tank design calculation pdf snow load

Next : cylindrical steel welding oil tank in SUG III