Prefabrication requirements of valuable storage capacity, large vertical storage tank wall panels:
1. The prefabrication of wall panel shall be processed in strict accordance with the requirements of the drawings, and inspection records shall be made.
2. After the wall panel is rolled, it should be placed on the platform for inspection with a template. In the vertical direction, use a straight-line template to check, the gap should not be greater than 2 mm, and in the horizontal direction, use an arc-shaped template to check, and the interval should not be greater than 4 mm.
3. When wall panels are rounded, attention should be paid to prevent irreversible plastic deformation caused by external forces. After rolling, it should be placed on the platform for inspection, and then placed on the prepared mold.

The company revolves around the long-term strategy of "building a quality base and building a century-long BEBON", adheres to the development ideas of innovation, transformation, and improvement, vigorously promotes transformation and upgrading, structural adjustment, energy conservation and emission reduction, and strives to create high-quality steel with strong core competitiveness and distinctive features The production base has become a green steel city with intensive land use, clean production, efficient use of resources, harmonious and friendly production and environment, business and society, and BEBON characteristics.

The horizontal projection of the roof plate within the compression-ring region is 4.9 x 0.866 = 4.25 in., which fulfills the requirement of API 620 tank standard 5.12.5.1. The required area and horizontal projection can be provided by any of the standard angles listed in Table F-3.
Any of these angles may be used in accordance with the details of Figure 5-6, detail a or b, but if details c, h, or i in Figure 5-6 were intended, the net area of the angle must be calculated by deducting the area expected to be lost by corrosion from that part of the angle surface that is exposed to the interior of the tank.

Previous : Store crude oil API650 tank bottom shell

Next : API620 crude oil storage tanks manufacturers metal temperature during hydrostatic testing