Design of Reinforcement for Single Openings in Tank Walls
The 20 in. x 29 in. obround manhole shown in Figure F-5 is located in solid plate in the sidewall of a cylindrical storage tank 45 ft in diameter in an area where the thickness of the wall plate, tw, is 1/2 in. No corrosion allowance is required. The total internal pressure, Pl + Pg, at the horizontal centerline of the opening is 27.5 lbf/in.2 gauge. The thickness of the wall plate, t, required by 5.10.3 for the latitudinal unit forces, T2, acting at this level is 0.485 in. The manhole neck is fabricated by welding from 3/8 in. plate. The materials in the API 620 tank wall, the manhole neck, and the reinforcing pad conform to ASTM A516 Grade 60. The joints in the welded steel storage oil tank wall and the longitudinal joint or joints in the manhole neck are double-welded butt joints, spot radiographed in accordance with 7.16 and 7.17.

The interior of API 650 storage tanks to be internally lined or coated must have all edges rounded to a minimum of 3 mm radius. Internal welds must be completely seal welded, ground smooth, and free from api 650 crude oil storage tank standard pdf surface porosity, pockets, and high spots. Remove weld spatter. Vendor as specified on API 650 storage tanks drawing must perform additional surface preparation.

Storage tank is used to store all kinds of liquid, solid and gas materials. The common types of storage tank are oil tank, water storage tank, chemical tank, cement tank, api 650 crude oil storage tank standard pdf, etc. When choosing the storage tank, users should choose according to their actual needs, such as the material, pressure, form, capacity, temperature, density, etc. In addition, the environmental factors such as the temperature of the tank construction area, the ground endurance of the foundation, and the wind force should be considered.

Previous : EN S355 plates api 620 crude oil storage tank free download pdf

Next : 1100 aluminum tube api 650 crude oil storage tank specification

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12