API620 crude oil storage tanks manufacturers heat-affected zone

API620 crude oil storage tanks manufacturers heat-affected zone

API620 crude oil storage tanks manufacturers heat-affected zone

Every after-sales service shall have a detailed record of the customer's product problems and handling methods. The records shall be sorted into volumes and filed on a monthly basis, and submitted to the technical department for filing. The problems found in the after-sales service shall be summarized in a timely manner, discussed with the technical department, the quality inspection department and the production department, and a proper solution shall be proposed for the technical department to improve in a timely manner;

Atmospheric API620 crude oil storage tanks manufacturers refer to storage tanks whose gas or vapor pressure is greater than -0.02MPa but less than 0.1MPa. Metal atmospheric storage tanks made of steel welded on the ground are often used to store petroleum, chemical and other similar liquids. Atmospheric API620 crude oil storage tanks manufacturers usually have a connecting pipe directly connected to the atmosphere, so that the operating pressure in the storage tank does not exceed the design pressure at all times.

Preheating should be performed by heating and maintaining this heat in appreciable lengths of the joint to be welded, preferably using a strip burner with a mild flame rather than a harsh flame such as that from a cutting torch. Electrical strip heaters are available and have been found to be satisfactory. The preheat of 300°F should be checked with a temperature-sensitive crayon, or similarly accurate means, so that the steel 4 in. (or four times the API620 crude oil storage tanks manufacturers plate thickness, whichever is greater) on each side of the joint will be maintained at the minimum preheat temperature. Ring burners or heaters are recommended for nozzle and manway welds. At no time during the welding should the base metal fall below a temperature of 300°F.

Previous : valuable storage capacity bottom plates

Next : Construction requirements for API 620 crude oil storage tank design