API620 welded low-pressure storage tank inspection qualification of welding procedures

For all API 620 crude oil tank other materials, the impact test temperature shall be at least 30°F colder than the design metal temperature. Alternately, materials impact tested at the design metal temperature or lower with Charpy impact test energy value of 25 ft-lb (average), 20 ft-lb (minimum) are acceptable for design metal temperatures above –40°F. API620 welded low-pressure storage tank inspection materials with an energy value of 30 ft-lb (average), 25 ft-lb (minimum) are acceptable for design metal temperatures of –40°F or lower.

The company regularly holds sales elites to share experiences, to promote the rapid growth of colleagues, and achieve the company and employees. The company conducts employee skill training and related knowledge video learning from time to time. All these things is to improve the employees' skills and literacy, and reflects its own value. It has always been the pursuit of BBN steel to enhance the employee’s ability and keep up with the times.

The company's logistics adopts the method of cooperation with logistics companies. As a third-party logistics company is engaged in the operation of multiple logistics projects, it can integrate various logistics resources, making the logistics operation cost relatively low and the logistics operations more efficient. Thus we can provide more professional logistics services, while also focusing on our core business of steel materials.

The foundation design of the API620 welded low-pressure storage tank inspection should meet the requirements of foundation stability and deformation, that is, the API620 welded low-pressure storage tank inspection foundation should not be crushed and the uneven settlement value of the foundation should be within the allowable range. The uneven settlement of the storage tank foundation should be specified in the design process of the safe allowable range, because excessive uneven settlement will reduce the safety of the API620 welded low-pressure storage tank inspection and cause distortion and deformation of the tank wall and bottom plate.