In this project, the area of tank wall used is of the same construction, material, and geometry as that described in F.1.3.1 except that the thickness of the plate is 3/8 in. The wall is stressed in the same manner as is described in F.1.3.1. A corrosion allowance of 1/16 in. is required. The computed (meridional) tensile stress, stc, in the net thickness after deduction of the corrosion allowance is 8000 lbf/in.2.
The problem in this example is to find the maximum allowable (latitudinal) compressive stress value for the given conditions, in conformance with the provisions of API 620 tank standard 5.5.4.5.
Solution: As determined from Table 5-1, the maximum allowable tensile stress value, Sts, for ASTM A285, Grade C, steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R in this situation is R1, or 75 in.

API 650 storage tank is used for commonly used oil, gasoline, diesel, chemical and production water storage. API650 petroleum storage tank Storage tanks built to these standards are spread across U.S. refineries, terminals, pipelines, and production facilities. The API 650 detailed standard specifies the design, processing, welding, inspection and installation procedures for storage tanks.

Comparison of the quality of mechanical cleaning and manual cleaning of vertical storage tanks, API650 petroleum storage tank. The mechanical cleaning of the API650 petroleum storage tank can make the inside of the tank be thoroughly cleaned in multiple directions, and the cleaning quality is high, and the cleaned oil does not contain lumpy impurities. While the walls and roof of the API650 petroleum storage tank cannot be cleaned in multiple directions during manual cleaning, and the cleaning quality is not easy to be guaranteed. The oily sewage collected after cleaning usually contains a lot of lumpy impurities, and these oil products are difficult to clean.

Previous : steel storage tank for oil distribution fittings and attachments

Next : Alclad 3003 aluminum plate API650 petroleum storage tanks

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12