24/7 Phone Services 0086(371)86151827
Send to E-mail [email protected]
[email protected] Xincheng Science & Technology Building High-Tech Development Zone, Zhengzhou, China

crude oil storage tank construction size

crude oil storage tank construction size

crude oil storage tank construction size

API 620 Tank Standard Post-heat Treatment (Stress Relief)
The post-heat treatment now performed on pressure vessels is of established value, although the mechanism by which the improvement is realized may be open to debate. Post-heat treatment of crude oil storage tank construction tank sections when the plate thickness exceeds 11/4 in. is required as stated in 5.25. In special cases, the possibilities of post-heat treatment after erection should be explored. Post-heating an insulated tank may be possible if an ample source of heat is readily available and if the rigidity of the tank is adequate.
The thermal stress-relief treatment performed on pressure vessels is recognized as a means for reducing the probability of brittle failures.

If additional requirements are met, higher internal pressures are allowed. API 650 only covers tanks that support the whole bottom evenly and crude oil storage tank construction tanks in non-refrigerated service that have a maximum design temperature of 200 degrees F. It requires that you have a minimum material thickness of 3/16 inch.

The specifications used in the design of large oil tanks, crude oil storage tank construction mainly include American Petroleum Institute Standard API 650, Japanese Industrial Standard JIS B8501, British Industrial Standard BS2654 and Chinese National Standard GB50341 from a global perspective. The formulas used in each specification are based on the hoop stress in the membrane theory. Each specification is based on the performance characteristics of materials and the construction technology level of their respective countries to determine the allowable stresses and weld coefficients. Therefore, the calculation results of tank wall thickness of crude oil storage tank construction with the same volume are sometimes quite different according to different specifications.

Previous : Construction requirements for API 620 crude oil storage tank design

Next : crude oil storage tank specifications limitations