24/7 Phone Services 0086(371)86151827
Send to E-mail [email protected]
[email protected] Xincheng Science & Technology Building High-Tech Development Zone, Zhengzhou, China

EN S355 plates api 620 tank inspection

EN S355 plates api 620 tank inspection

EN S355 plates api 620 tank inspection

The elastic filling and sealing of floating roof api 620 tank inspection is to fill the elastic and changeable objects in the sealed envelope, and the sealing purpose depends on the compression deformation of the filler. This kind of sealing effect is good, the requirement of the geometry of tank wall is not too high, and the adaptability is strong. However, the elastic filling and sealing has poor wear resistance and is easy to deform and damage in long-term use.

BBN company is a modern enterprise integrating steel producing, warehousing and logistics, processing and distribution. We are committed to creating a "one-stop steel procurement service" platform. The main products are I-beam, angle steel, api 620 tank inspection , H-beam, hot-rolled coil, welded pipe, spiral pipe seamless pipe and many other steel products. Standing stocks amount to more than 30,000 tons, and complete specifications, the company gradually moves towards large-scale distribution enterprises with serialized products, standardized services and modern transportation management.

The after-sale service of iron and steel products includes after-sale tracking service, technical guidance, transfer of relevant bills, handling of objections and many other contents. The handling of quality objections accounts for a large proportion. When dealing with these problems, we should distinguish the responsibilities, and compensate or return the inconvenience or loss caused to users due to steel.

Uplift on Foundation
For API Standard 620 tanks with an internal design pressure less than 1 lbf/in.2 gauge, the uplift shall be taken as the smaller of the maximum uplift values computed under the following conditions:
a)The internal design pressure times 1.5 plus the design wind load on the shell and roof.
b)The internal design pressure plus 0.25 lbf/in.2 gauge plus the design wind load on the shell and roof.

Previous : API620 tank pressure limit roof structure

Next : api standard 620 vs api 650 tank shell attachments and tank appurtenances

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12