24/7 Phone Services 0086(371)86151827
Send to E-mail [email protected]
[email protected] Xincheng Science & Technology Building High-Tech Development Zone, Zhengzhou, China

ISO 630 Gr E275 plates low pressure storage tank

ISO 630 Gr E275 plates low pressure storage tank

ISO 630 Gr E275 plates low pressure storage tank

The pressed-steel, round manhole with a 20-in. inside diameter shown in Figure F-8 is located in API 620 crude oil tank solid plate in spherical portion of a torispherical roof on a cylindrical storage tank 72 ft in diameter. The internal pressure, Pg, on the underside of the roof is 15 lbf/in.2 gauge. The thickness, t, of the roof plate required by 5.10.3 for the spherical portion of the roof is 1/2 in., which is exactly the thickness provided. No corrosion allowance is required. The materials in the oil tank roof plates and manhole frame conform to ASTM A283 Grade C steel; the main joints in the roof are double-welded butt joints, spot radiographed in accordance with 7.16 and 7.17.

In view of the characteristics of container transportation, such as high added value, low cargo damage and short time, our company takes more consideration of port collection and distribution conditions, port facilities, flight density and route coverage when choosing ports. For the convenience of customers, as well as the safety of goods.

API 650 internal floating roof oil tank is a volatile liquid storage tank with a combination of a dome tank and an internal floating roof structure, which is a floating roof assembled under the dome of the low pressure storage tank storage tank. The combination of the vault roof outside the API 650 storage tank and the floating roof inside the tank has been widely used in gasoline, aviation kerosene and more volatile chemical liquids.

Requirements for prefabrication of the top of large vertical low pressure storage tank: The prefabrication of the tank top shall be prefabricated in blocks according to the drawings. Pay attention to the spacing of the welds after installation when setting out the material. Reinforcing ribs should be formed and inspected with an arc-shaped template. When a single top plate needs to be spliced, butt joints should be used. The forming of a single top plate should be welded between the reinforcing ribs and the top plate on the mould. After forming, check with an arc-shaped sample plate, and the gap should not be greater than 10 mm.

Previous : API620 cylindrical tanks internal components

Next : API 620 vertical storage tank sheets

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12