24/7 Phone Services 0086(371)86151827
Send to E-mail [email protected]
[email protected] Xincheng Science & Technology Building High-Tech Development Zone, Zhengzhou, China

API 620 cryogenic liquid storage tank price

API 620 cryogenic liquid storage tank price

API 620 cryogenic liquid storage tank price

Soil Structure Interaction: Soil structure interaction per API 650, Section E.6.1.6 may be used for OLE design providing the damping ratio does not exceed 10 %.
Allowable Stresses
Design allowable stresses shall be per API 620 large welded steel storage tank, Section Q.3.3, including the 33 % increase permitted for earthquake loads.


Self-anchored Inner Tank
The anchorage ratio for a self-anchored inner tank, J, shall not exceed 1.0 for the OLE design combination to limit uplift and stresses in the annular plate and corner weld.
Foundation Stability
The overturning ratio defined in API 650, Section E.6.2.3, Equation (E.6.2.3-1) shall be equal to or greater than 3.0 for the defined OLE event.

BBN employees work hard and work hard in their work. In life, colleagues care about each other, like a family, and accompany each other at important moments in life. BBN Steel organizes employees to carry out tourism activities every year, so that families can be exposed to nature and relax physically and mentally. The good combination of working and rest can achieve the goal of hard work and happy life.

Previous : api oil storage tank standards annular bottom plates

Next : A841 grade B plates difference between api 650 and api 620 tank

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12