During heavy rain, closely observe the change of the water level in the storage area of the API 620 oil storage tank material. If the water level rises to the dangerous range, drain the water immediately. There are more thunderstorms in heavy rain, and lightning protection devices should be installed in the API 620 oil storage tank material area to avoid lightning accidents. Observe the groundwater level of the API 620 oil storage tank material area at any time, clean and dredge the drainage ditch in time to ensure unobstructed drainage, and prevent the bottom of the API 620 oil storage tank material from leaking and rusting due to untimely drainage.

Since its inception, the company has always adhered to the development policy of "survival with quality, development with products, cooperation with credibility, and service with customers". I would like to express my heartfelt thanks to the old and new friends and customers who have always given care, support and help to the company! And sincerely hope to establish a long-term cooperative relationship with them, mutual benefit and common development.

Inspection of low-pressure storage tank Butt-weldsComplete penetration and complete fusion is required (to the degree mandated by the acceptance criteria for examination method utilized) for welds joining tank wall plates to API 620 oil storage tank material tank wall plates. Examination for quality of welds shall be made using either the radiographic method specified in API 620 standard 7.15.1 and applied in 7.17, or alternatively, by agreement between the Purchaser and the Manufacturer, using the ultrasonic method specified in 7.15.3.1. In addition to the radiographic or ultrasonic examination, these welds shall also be visually examined as specified in 7.15.5. Furthermore, the Purchaser’s inspector may visually inspect all butt-welds for cracks, arc strikes, excessive undercuts, surface porosity, incomplete fusion, and other defects.

Previous : api 620 welded storage tanks flat-face pipe flange

Next : API 620 low-pressure oil storage tanks reinforcing plates

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12