Prefabrication requirements of steel lined plastic storage tank, large vertical storage tank wall panels:
1. The prefabrication of wall panel shall be processed in strict accordance with the requirements of the drawings, and inspection records shall be made.
2. After the wall panel is rolled, it should be placed on the platform for inspection with a template. In the vertical direction, use a straight-line template to check, the gap should not be greater than 2 mm, and in the horizontal direction, use an arc-shaped template to check, and the interval should not be greater than 4 mm.
3. When wall panels are rounded, attention should be paid to prevent irreversible plastic deformation caused by external forces. After rolling, it should be placed on the platform for inspection, and then placed on the prepared mold.

Every customer who has visit us and witness the steel materials before delievry will be impressed by our quality control departemnt. Even not come to inspect the steel materials before delievry, our quality control departemnt will also send inspection report to the customer.

API 620 Tank Standard Post-heat Treatment (Stress Relief)
The post-heat treatment now performed on pressure vessels is of established value, although the mechanism by which the improvement is realized may be open to debate. Post-heat treatment of steel lined plastic storage tank tank sections when the plate thickness exceeds 11/4 in. is required as stated in 5.25. In special cases, the possibilities of post-heat treatment after erection should be explored. Post-heating an insulated tank may be possible if an ample source of heat is readily available and if the rigidity of the tank is adequate.
The thermal stress-relief treatment performed on pressure vessels is recognized as a means for reducing the probability of brittle failures.

Previous : construction of API620 low-pressure storage tanks uplifting force and downward weights

Next : API 620 chemical storage tank local deviations