Density of API620 conical-roof tank Liquid Stored
The density of the liquid stored shall be its maximum density within the range of design temperatures, but no less than 29.3 lbf/ft3 for methane, 34.21 lbf/ft3 for ethane, and 35.5 lbf/ft3 for ethylene.
Design Metal Temperature
The design metal temperature of each component exposed to the liquid or vapor being stored shall be the lower of the temperatures specified as follows: The design metal temperature of the components of the API 620 single-wall tank or the inner tank of a double-wall tank shall be the minimum temperature to which the tank contents shall be refrigerated, including the effect of subcolony at reduced pressure.

API 650 storage tank, double-layer oil tank environmental protection advantages: ordinary single-layer steel API620 conical-roof tank oil tank is corroded by underground water and gas and electrolytic corrosion because it is buried underground all year round. The API 650 tank has a double-layer structure with a gap of 0.1 mm. The API620 conical-roof tank outer layer of FRP ensures that the leakage will not directly leak into the soil and water source.

Enterprise Motto:Integrity, harmony, dedication, innovation and developmentAbility is the cornerstone of success; action is the ladder of successGrow with the enterprise; progress with the enterpriseGive a platform to those who actually do things and a stage to those who successfully do thingsDare to be the first, to pursue excellence.

Under the condition of static storage without receiving and sending operation, the temperature of gas space, evaporation rate, depth and pressure of vapor in the API620 conical-roof tank will change with the change of temperature and pressure in a day. The oil loss caused by the process of discharging oil vapor and inhaling air gas is called "small breathing" loss, which is also called static storage loss of oil tanks.

Previous : API620 conical-bottom tank primary seals

Next : API650 spherical tank sidewall plate material top wind girder