Requirements for prefabrication of the top of large vertical API620 dome-roof storage tank: The prefabrication of the tank top shall be prefabricated in blocks according to the drawings. Pay attention to the spacing of the welds after installation when setting out the material. Reinforcing ribs should be formed and inspected with an arc-shaped template. When a single top plate needs to be spliced, butt joints should be used. The forming of a single top plate should be welded between the reinforcing ribs and the top plate on the mould. After forming, check with an arc-shaped sample plate, and the gap should not be greater than 10 mm.

Welding of API 620 Steel Storage Tank Primary Components
The following primary components shall be joined with double butt-welds that have complete penetration and complete fusion except as noted:
Longitudinal and circumferential shell joints and joints that connect the annular bottom plates together. When approved by API620 dome-roof storage tank Purchaser, these may be welded from a single side provided temporary non-fusible backing is used with complete penetration and complete fusion. Both sides of the joint shall be 100% visually examined as specified in 7.15.5.

Large net shell API 650 tanks or net shell of tank API620 dome-roof storage tank is a tank top for the surface grid structure and the physical structure form of truss structures, thin shell structure is reasonable, mainly for the top using triangle net shell, socket type net shell or meridian reticulated shell technology for the design of API620 dome-roof storage tank large-scale tank top, its great spanning capacity and uniform stress, good rigidity, less material, convenient assembly, safe and reliable.

In December of 2015, our regular India customer sent us an inquiry for API620 dome-roof storage tank pipe. The inquiry requires no negative tolerance in both pipes’ outer diameter and pipe wall. After two weeks’ discussion, he put the order of 275 tons to us. The pipes are finished within just one month. Our customer come to our factory to inspect the quality and tolerance, all the products are well meet his demand. The pipes are arriving to Nhava Sheva port, customer is very happy with our products and service during the process.

Previous : api 620 welded storage tanks astm a516 grade 60 plate

Next : API620 conical-bottom tank minimum thickness of nozzle neck