Crack treatment of API620 volatile oil steel storage tanks weld area: find out the crack tip with ray or ultrasonic flaw detection, drill cut-off holes at both ends of the crack with the cut-off method, the hole depth is slightly greater than the crack depth, or groove (crack stop groove) is made by angle grinder at both ends of the crack, shovel and grind the whole crack, and grind it into a suitable groove; use radiographic inspection and dye detection to verify that the crack has been completely excavated, and finally repair welding.

According to API Standard 650, the stairs used for API 650 petroleum storage tanks or thermal insulation tanks should be double longitudinal beams supported by a minimum of ribs. If the gap between the API620 volatile oil steel storage tanks tank shell and the stringer of the API 650 petroleum storage tank exceeds 200mm, handrails should be provided on both sides of the stairs. Unless otherwise specified, according to API620 volatile oil steel storage tanks ASTM A123, the following accessories shall be hot-dip galvanized. The damaged zinc coating should be repaired with zinc alloy.

In this project, an elemental area of tank wall used is constructed of ASTM A442 Grade 55 steel plate subjected to a meridional unit force, T1, of 4000 lbf/in.2 tension and a latitudinal unit force, T2, of 5060 lbf/in.2 compression. The meridional radius of curvature, R1, is 75 in., and the length of the normal from the surface to the axis of revolution, R2, is 300 in. The joints in the wall are of double-welded butt-joint construction with a tensile efficiency of 85%. A corrosion allowance of 1/16 in. is required.
The problem in this example is to graphically find the minimum thickness of tank wall required for the given conditions (see 5.10.3.3).
Solution: As determined from Table 5-1, the maximum allowable tensile stress value, Sts, for ASTM A442 Grade 55 steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R in this situation is R1, or 75 in.

The company has passed the ISO9001: 2008 quality system certification, strictly implemented the ISO9001 quality management system. Besides, we have continuously improved the after-sales service network to make every effort to provide more convenient, accurate and faster services for all customers. We will supervise the production, control the quality in the factory, Inspect the cargo before shipment, Issue the test report to sales department. From the steel prodcution to steel delivery, we always focus the whole process.

Previous : API oilfield steel storage tanks for sale

Next : steel storage tank for oil transporation lining

Leave a message

Client Image 1
Client Image 2
Client Image 3
Client Image 4
Client Image 5
Client Image 6
Client Image 7
Client Image 8
Client Image 9
Client Image 10
Client Image 11
Client Image 12